Omnigate
PLCs ↔ MQTT · InfluxDB · OPC UA, zero code
Industrial gateway connecting PLCs (Omron, Siemens, Modbus, EtherNet/IP, OPC UA) to your modern data stack: MQTT, InfluxDB 2.x, embedded OPC UA server and Home Assistant Discovery. Web-configurable, hot-reload, single Go binary ~14 MB.
Request demoProblems Innex solves
Omron, Siemens, Modbus, Allen-Bradley… each PLC speaks its own protocol. Bridging to MQTT or InfluxDB needs custom code.
Migrating variable maps from Sysmac Studio costs days of manual transcription and typos.
Your legacy SCADA only speaks OPC UA but modern PLCs no longer expose a server. You need a bridge.
What Innex does
6 inbound PLC protocols
Omron FINS/TCP+UDP, Siemens S7, multi-slave Modbus TCP, EtherNet/IP CIP, OPC UA client. One gateway for the whole plant.
4 parallel outputs
MQTT (own broker, HiveMQ, AWS IoT), InfluxDB 2.x (~2,300 points/s), embedded OPC UA server and Home Assistant Discovery.
Smart coalescing
In a 16-bit UDT it reads 1 word and extracts the bits. 16× less PLC traffic than naive polling, without losing granularity.
Full hot-reload
Add variables, change host/port, enable HA Discovery — all applied live. Propagation < 1 second, no service restart.
Sysmac importer
sysmac2omnigate converts an Omron project into omnigate.json with one command. Tested on installations with 318 instances and 2,500+ variables.
Real results
How it works in your company
Install the binary
Linux or Windows. Native service (no NSSM), 14 MB. Less than 5 minutes to the first value on MQTT.
Configure from the web
Build-less UI. Add PLCs, variables and destinations from the browser. No hand-edited JSON.
Map the variables
Reusable data types (structs). Instancing is one click: memory address + struct → all field variables generated automatically.
Publish anywhere
MQTT with configurable QoS, batched InfluxDB writes, OPC UA Server for legacy SCADAs, HA Discovery for Home Assistant. All at once if needed.
Monitor live
Per-PLC performance panel: blocks/s, latency, errors, drops. Anomaly detection over a 240 s sliding window.
Included features
PLC protocols
- Omron FINS/TCP + UDP (NX/NJ, CJ)
- Siemens S7-300/400/1200/1500
- Multi-slave Modbus TCP
- EtherNet/IP CIP (Allen-Bradley, Omron ENIP)
Output destinations
- MQTT (HiveMQ, Mosquitto, AWS IoT)
- InfluxDB 2.x (native line protocol)
- Embedded OPC UA Server (for SCADAs)
- Home Assistant MQTT Discovery
Plans
- Demo · 10 variables, free
- Standard · 100 variables + S7
- Pro · 1,000 variables + InfluxDB + EIP
- Enterprise · 5,000 variables + OPC UA Server
Who is Innex for?
Machine OEMs
Mini-PC next to the PLC and MQTT to HiveMQ or AWS IoT. Offer "OEE in the cloud" without touching the machine control logic.
Heterogeneous PLC plants
Omron, Siemens and Modbus coexisting: one gateway feeds InfluxDB+Grafana with unified history and consistent dashboards.
Home Assistant integrators
Variables show up in HA automatically via MQTT Discovery. Sensor, switch and number entities by configuration, no hand-written YAML.